Commercial HVAC rooftop installation

High-Efficiency HVAC Systems, AirMaster Pro Reliability You Can Count On

From chillers to custom air handlers, we engineer commercial and industrial climate control solutions designed for peak performance, energy efficiency, and decades of dependable operation.

35+ Years of Engineering Excellence
18,000+ HVAC Units Annually
45 Countries Served
35 Service Centers Worldwide

Our HVAC Product Range

Comprehensive commercial and industrial climate control equipment engineered for performance, efficiency, and long-term value.

Commercial Rooftop HVAC Units

Commercial Rooftop Units

Packaged and split-system rooftop units from 2 to 200 tons, featuring variable-speed compressors and integrated economizers for optimal efficiency.

Request Specifications →
Air-Cooled Chillers

Air-Cooled Chillers

Screw and scroll air-cooled chillers from 30 to 500 tons with industry-leading IPLV ratings, built for continuous commercial and process cooling.

Request Specifications →
Water-Source Heat Pumps

Water-Source Heat Pumps

High-COP water-source and geothermal heat pumps for simultaneous heating and cooling, ideal for multi-zone commercial buildings.

Request Specifications →
Custom Air Handling Units

Custom Air Handling Units

Fully configurable AHUs with variable-air-volume controls, energy recovery wheels, and MERV 13+ filtration for demanding applications.

Request Specifications →
Condensing Units

Condensing Units

Air-cooled condensing units from 1 to 60 tons for commercial refrigeration and split-system HVAC, with low-sound fan assemblies.

Request Specifications →
Self-Contained HVAC Systems

Self-Contained Systems

Indoor self-contained units for retrofit and space-constrained applications, delivering heating, cooling, and ventilation in a single package.

Request Specifications →

Industries We Serve

Purpose-engineered HVAC solutions for facilities where climate control is mission-critical.

Why Facility Managers Choose AirMaster Pro

Dependable performance backed by engineering depth and a nationwide service commitment.

Engineered Efficiency

Our systems consistently achieve IPLV ratings that exceed ASHRAE 90.1 minimums, lowering lifecycle energy costs for your facility.

AHRI Certified

Every product line is AHRI-certified and UL-listed, giving procurement teams verified performance data they can trust.

Rapid Response

With 35 service centers, our certified technicians deliver emergency response within 8 hours and carry genuine replacement parts.

Custom Engineering

Our 180-strong engineering team delivers custom-configured systems for unique building requirements, from design through commissioning.

Representative Project Outcomes

Measurable results from recent installations across our core sectors.

Healthcare Campus Retrofit

Scope: Replacement of aging 1990s-era rooftop units and centrifugal chillers across a three-building, 420,000 sq ft regional medical center in the southern United States.

Solution: 14 variable-speed rooftop units (8-25 tons each) paired with two 200-ton air-cooled screw chillers, both operating on R-454B refrigerant. Integrated with the facility's existing BMS via BACnet protocol.

Result: 32% reduction in annual cooling energy expenditure verified through 12-month utility bill comparison. Measured IPLV of 0.52 kW/TR, exceeding the ASHRAE 90.1-2022 minimum by 18%.

Data Center Refrigerant Transition

Scope: In-place refrigerant conversion for a 2.4 MW Tier III colocation data center in Atlanta, GA, transitioning from R-410A to R-454B without compromising uptime SLA requirements.

Solution: Phased conversion of 12 precision cooling units over 6 months, using temporary supplemental cooling during each unit's 72-hour conversion window. All work performed during low-demand overnight periods.

Result: Zero unplanned downtime during the transition. Post-conversion COP improved from 3.1 to 3.5 due to optimized charge and updated EEV settings. Annual refrigerant GWP footprint reduced by 78%.

University Campus Expansion

Scope: New-construction HVAC for a 180,000 sq ft science and engineering building at a Midwest public university, requiring laboratory fume hood exhaust makeup, lecture hall VAV, and server room precision cooling.

Solution: Custom AHU with energy recovery wheel (75% enthalpy effectiveness), 120-ton water-source heat pump loop serving 48 zones, and dedicated 15-ton DX unit for the 2,000 sq ft server room.

Result: Building achieved ASHRAE 90.1-2022 compliance with 22% energy use intensity below baseline. Indoor air quality consistently maintained above ASHRAE 62.1 requirements across all occupied zones during first academic year.

Ready to Engineer Your Ideal Climate Solution?

Our project engineers will evaluate your facility requirements and recommend the most cost-effective system configuration.